Neogen® Molecular Detection Assay 2 Quantitative Salmonella

MDA2 QSal

SKU No.  700006924  |  Catalog No.  MDA2QSAL96

  • Lower limit of quantitation 1 CFU/mL sample (rinses), 1 CFU/g (meat).
  • Accuracy within +/-0.5 log 95% CI when compared to MPN at 6 hours of enrichment in QRED media.
  • Cloud-based models available are nBPW and BPW poultry rinses and raw ground poultry (chicken and turkey).
  • Quantitative Rapid Enrichment Dehydrated (QRED) media designed to enable controlled growth rates for quantitation.
  • Molecular Detection Assay kits with a controlled manufacturing process to provide lot to lot consistency.
Qty:
Minimum quantity required: 1
This item must be ordered in multiples of one case. Quantity per case: 1
As with all test methods, the source, formulation and quality of enrichment medium can influence the results. Neogen® has evaluated the Neogen® Molecular Detection Assay 2 - Quantitative Salmonella with Quantitative Rapid Enrichment Dehydrated Media.
Specifications
BrandNeogen® Molecular Detection System
AnalyteSalmonella
SpeciesPoultry
PlatformMolecular Detection System
Result TypeQuantitative
Time to Result6 Hours
Storage Conditions2-8°C | Do not freeze
Case Count1
Quantity per Package96 tests
Package Weight0.70 lb
  1. 96 Lysis Solution (LS)
  2. 96 Molecular Detection Assay 2Q - Quantitative Salmonella Reagent Tubes
  3. 96 Extra caps
  4. 16 Reagent Control (RC)
  1. Neogen® Molecular Detection Instrument and Accessory Kit (Neogen item: 700002195|MDS100)
  2. Neogen® Molecular Detection Matrix Control (Neogen item: 700002079|MDMC96NA)
  3. Neogen® Molecular Detection Cap/Decap Tool - Lysis (Neogen item: 700000142|MDSCDL)
  4. Neogen® Molecular Detection Cap/Decap Tool - Reagent (Neogen item: 700000141|MDSCDR)
  5. Neogen® Molecular Detection Heat/Chill Block Insert (Neogen item: 700000145|MDSHBIN)

Technology

Powered by an innovative combination of unique technologies to bring molecular level accuracy expected by customers – without sacrificing productivity.

The Molecular Detection System use Loop-Mediated Isothermal Amplification (LAMP) to amplify specific regions of the DNA with high sensitivity and specificity.

Training

Our customers’ success is our shared success. Our experts are ready to train you and your team on our solutions, so you can rest easy knowing procedures are performed properly and yield accurate results. In addition, we provide certificates upon completion of training to provide you with the documentation needed for audit traceability.